How To Use Rouster Bout
   
            (scroll down)
Close Window
and Return Home
1 - Fill solution tank with 10 gallons of clear water.
2 - Add 2 gallons of Rouster Chem concentrate. Check pH level with optional pH meter or paper strips to ensure it is between 2.0 and 5.0. Over time the solution does weaken. If the pH is higher than 6.0 it may not be effective. The pH can be lowered by adding Rouster Chem concentrate directly to the existing solution. The lower the number the more aggressive the descaling action.
3 - Blow air through mold or heat exchanger (or any other deviceto be treated) lines to remove standing water. Attach pressure hose from Rouster Bout pump to "IN" line at mold (or other device).
4 - Attach return hose to "OUT" line at mold (or other device). Return line has filter unit on it.

Pump will lift solution from the tank reservoir after starting. This should only take a few seconds to occur. If it does not start lifting solution there may be a kink in the line or the tank may not be filled enough.

DO NOT ALLOW PUMP TO RUN DRY - DO NOT ALLOW PUMP TO RUN DRY

Note: If reducers or couplers must be used, attach them to the Rouster Bout hose ends, not to the pump connections. If Rouster Bout pump connections must be replaced use only identical sized fittings and be careful not to exert excessive force or the pump and/or solution tank may be permanently damaged. This damage is NOT covered by our warranty.
5 - Start circulation by inserting electrical plug in a proper GFI outlet.
6 - Circulate water for proper time. If at room temperature, water must circulate for at least 20 minutes. If mold (or other device) has just been shut down, see chart below for proper time settings. A warm device will activate the cleaning solution faster than a cold device. DO NOT USE AT OVER 100 F.
7 - Stop circulation by removing electrical plug from outlet. (If an on-off switch is desired please contact a certfied electrician to install).
8 - Remove Rouster Bout connecting hoses from the mold (or other device).
9 - Blow a stream of air through the device lines until dry, to keep the lines from rusting.
10 - If mold (or other device) will not be used immediately use proper rust preventive in water lines.
11 - Check and clean return line filter screen. This should be done every time the Rouster Bout is used as a clogged filter may cause damage to the pump unit. An increased pressure reading on dial gauge indicates a clogged filter.

If disposing of a tank of solution, add Rouster Chem Neutralizer (approximately 1 pound per 5 gallons solution) to bring the pH level to a "safe-disposal level" of between 5.0 and 9.5 with 7.0 being ideal.

NOTE: The cleaning solution works faster when it is warm. The total time for circulating the solution at varying temperatures is shown in the following table:

Temperature of mold              Cleaning time required
60 F                                        60 minutes
70 F                                        40 minutes
80 F                                        20 minutes
90 F                                        10 minutes
DO NOT USE AT TEMPERATURES ABOVE 100 F OR BELOW 40 F, OR SOLUTION BECOMES INEFFECTIVE, PUMP IMPELLER WILL SEIZE, AND FITTINGS MAY WARP, CRACK, AND LEAK. WARRANTY DOES NOT COVER THIS.